20 research outputs found

    Trade-Off between Task Accuracy, Task Completion Time and Naturalness for Direct Object Manipulation in Virtual Reality

    Get PDF
    Virtual reality devices are used for several application domains, such as medicine, entertainment, marketing and training. A handheld controller is the common interaction method for direct object manipulation in virtual reality environments. Using hands would be a straightforward way to directly manipulate objects in the virtual environment if hand-tracking technology were reliable enough. In recent comparison studies, hand-based systems compared unfavorably against the handheld controllers in task completion times and accuracy. In our controlled study, we com-pare these two interaction techniques with a new hybrid interaction technique which combines the controller tracking with hand gestures for a rigid object manipulation task. The results demonstrate that the hybrid interaction technique is the most preferred because it is intuitive, easy to use, fast, reliable and it provides haptic feedback resembling the real-world object grab. This suggests that there is a trade-off between naturalness, task accuracy and task completion time when using these direct manipulation interaction techniques, and participants prefer to use interaction techniques that provide a balance between these three factors.publishedVersionPeer reviewe

    Ultra-low-dose CBCT scan : rational map for ear surgery

    Get PDF
    Purpose: This study will evaluate the clinical quality and usability of peripheral image data from the temporal bone area obtained using a sinonasal ultra-low-dose (ULD) cone-beam computed tomography (CBCT) scan and compare them to those obtained using a high-resolution (HR) CBCT. Methods: The population consisted of 66 anatomical sites (ears of 33 subjects) imaged using two modalities: an HR CBCT (Scanora 3Dx scanner; Soredex, Tuusula, Finland) and a ULD CBCT (Promax 3D Mid scanner; Plandent, Helsinki, Finland). The image quality (IQ) for every anatomical site in each image was rated using a Likert scale from 0 to 5. Results: The quality of ULD CBCT scans was clinically sufficient in over 95% of the assessed images of the sigmoid sinus, jugular bulb, epitympanum and mastoid antrum as well as external acoustic meatus (all p > 0.05 compared to HR CBCT). The IQ was clinically sufficient in 75–94% of the assessed images of the scutum, mastoid segment of the facial nerve, cochlea and semicircular canals (all p < 0.05 compared to HR CBCT). The overall IQ of the HR CBCT scans was good or excellent. Conclusion: CBCT imaging and the data at image margins are underutilized. CBCT can produce excellent structural resolution with conventional imaging parameters, even with off-focus images. Using ultra-low doses of radiation, the produced IQ is clinically sufficient. We encourage ear surgeons to check the patients’ imaging history and to consider the use of imaging modalities that involve lower radiation doses especially when conducting repetitive investigations and with children.publishedVersionPeer reviewe

    Comparison of a VR Stylus with a Controller, Hand Tracking, and a Mouse for Object Manipulation and Medical Marking Tasks in Virtual Reality

    Get PDF
    In medical surgery planning, virtual reality (VR) provides a working environment, where 3D images of the operation area can be utilized. VR allows 3D imaging data to be viewed in a more realistic 3D environment, reducing perceptual problems and increasing spatial understanding. In the present experiment, we compared a mouse, hand tracking, and a combination of a VR stylus and a grab-enabled VR controller as interaction methods in VR. The purpose was to investigate the suitability of the methods in VR for object manipulation and marking tasks in medical surgery planning. The tasks required interaction with 3D objects and high accuracy in the creation of landmarks. The combination of stylus and controller was the most preferred interaction method. According to subjective results, it was considered as the most appropriate because it allows the manipulation of objects in a way that is similar to the use of bare hands. In the objective results, the mouse interaction method was the most accurate.publishedVersionPeer reviewe

    Diagnosis of Newly Delivered Mothers for Periodontitis with a Novel Oral-Rinse aMMP-8 Point-of-Care Test in a Rural Malawian Population

    Get PDF
    A novel qualitative point-of-care test of activated matrix metalloproteinase-8 (aMMP-8) using noninvasive oral rinse sampling procedures has been developed for the early detection of collagen breakdown indicating periodontal tissue destruction. The main object of this study was to assess the reliability of the test in a low-income setting to identify participants with history of periodontal destruction detected as alveolar bone loss (ABL) in radiographs. This cross-sectional study included 486 women who had recently delivered in rural Malawi. The aMMP-8 test and dental panoramic radiographs were taken within 48 h of delivery. The performance of the test in comparison to radiological examinations was tested by following the standards for reporting of diagnostic accuracy studies protocol (STARD) with respective statistical measures and 95% confidence intervals. From the 486 eligible participants, 461 mothers with complete data, aged from 15 to 46 years (mean 24.8, SD 6.0) were included in the analysis. ABL was identified in 116 of 461 participants. There was 56% agreement between the aMMP-8 test results and detected ABL (yes or no) in radiographs. Calculated sensitivity of the test was 80% (72–87%), specificity 48% (43–54%), positive predictive value 34% (31–37%), negative predictive value 88% (83–91%), positive likelihood ratio 1.55 (1.35–1.77), and negative likelihood ratio 0.41(0.28–0.60). The aMMP-8 test sensitivity and negative predictive value to identify the ABL cases were relatively high, but there was additionally a high rate of test-positive results in participants without ABL, especially in young mothers, leading to low overall agreement between the test results and radiological bone loss. Further longitudinal studies are needed to examine if the test positive subjects are in risk of future bone loss before the detectable signs of periodontitis in radiographs.Peer reviewe

    MRI of odontogenic maxillofacial infections : diagnostic accuracy and reliability

    Get PDF
    Objectives: To determine the diagnostic accuracy of emergency magnetic resonance imaging (MRI) in odontogenic maxillofacial infections, the clinical and surgical significance of MRI findings, and whether MRI can identify the tooth responsible for the infection. Methods: A retrospective cohort study reviewed 106 emergency neck MRI scans of patients with neck infections of odontogenic origin. The diagnostic accuracy of MRI in identifying abscesses was studied relative to surgical findings. Correlations were analyzed between various MRI findings and clinical results and outcomes, such as the surgical approach (intraoral vs. extraoral). The ability of MRI findings to predict the causative tooth was assessed in a blinded multi-reader setting. Results: Of the 106 patients with odontogenic infections, 77 (73%) had one or more abscesses. Imaging showed a sensitivity, specificity, and accuracy of 0.95, 0.84, and 0.92, respectively, for MRI diagnosis of an odontogenic abscess. Among the imaging findings, mediastinal edema was the strongest predictor of extraoral surgery. MRI showed bone marrow edema in the majority of patients, and multi-reader assessment showed good reliability. MRI was also able to predict the causative tooth accurately. Conclusions: Emergency neck MRI can accurately detect odontogenic abscesses and reliably point to the causative tooth. These results can increase the utility and reliance on emergency MRI in clinical decision-making.publishedVersionPeer reviewe

    MRI of odontogenic maxillofacial infections: diagnostic accuracy and reliability

    Get PDF
    Objectives To determine the diagnostic accuracy of emergency magnetic resonance imaging (MRI) in odontogenic maxillofacial infections, the clinical and surgical significance of MRI findings, and whether MRI can identify the tooth responsible for the infection.Methods A retrospective cohort study reviewed 106 emergency neck MRI scans of patients with neck infections of odontogenic origin. The diagnostic accuracy of MRI in identifying abscesses was studied relative to surgical findings. Correlations were analyzed between various MRI findings and clinical results and outcomes, such as the surgical approach (intraoral vs. extraoral). The ability of MRI findings to predict the causative tooth was assessed in a blinded multi-reader setting.Results Of the 106 patients with odontogenic infections, 77 (73%) had one or more abscesses. Imaging showed a sensitivity, specificity, and accuracy of 0.95, 0.84, and 0.92, respectively, for MRI diagnosis of an odontogenic abscess. Among the imaging findings, mediastinal edema was the strongest predictor of extraoral surgery. MRI showed bone marrow edema in the majority of patients, and multi-reader assessment showed good reliability. MRI was also able to predict the causative tooth accurately.Conclusions Emergency neck MRI can accurately detect odontogenic abscesses and reliably point to the causative tooth. These results can increase the utility and reliance on emergency MRI in clinical decision-making.</p

    The dental infections in patients undergoing preoperative dental examination before surgical treatment of saccular intracranial aneurysm

    Get PDF
    Abstract Objective Dental bacterial DNA and bacterial-driven inflammation markers have previously been detected in intracranial aneurysm tissue samples. This study aimed (i) to assess the possible presence of dental infectious foci, (ii) and the possible association between typical odontogenic bacteria and clinical dental findings in patients undergoing pre-operative dental examination before surgical treatment of saccular intracranial aneurysm. Ninety patients with an intracranial aneurysm were recruited to the study, and the patients’ teeth were routinely investigated. Clinical data and bacterial samples from the gingival pockets were collected from a subpopulation of 60 patients. Five typical dental pathogens and total bacteria amounts were measured from gingival samples using real-time quantitative PCR. Results The amounts of total bacterial and Fusobacterium nucleatum DNA were significantly higher in the patients with ≥ 6 mm gingival pockets than patients without them (p < 0.01 and p < 0.01, respectively). A total of 43% of patients with an aneurysm had gingival pockets of 6 mm or deeper. Dental infectious foci are fairly common in the Finnish population, with the prevalence of severe periodontitis being around 20%. The frequency of chronic dental infections, especially periodontitis seems to be higher in patients with intracranial aneurysm
    corecore